  • OEM Icon

    OEM 無創血壓技術

    我們的技術。你的解決方案。

    Adv Mx 模塊具有卓越的抗運動性能,通過了復雜的震動測試,能迅速準確地獲得可靠的血壓數據。 1)在各種的臨床應用環境中性能優異 2)Advantage RMT-Max (Maximum Performance R-wave Motion Tolerance) 具備心電門控抗運動功能 3)符合醫療設備第三版及Rohs要求 4)TTL通訊串口 5)抗運動性能最強 用于轉運環境

    Advantage MX 模塊

    技術規格


    Physical Dimensions

    SPECIFICATIONS VALUES
    Width 2.5 in [63.5 mm]
    Length 3.1 in [78.7 mm]
    Height 0.87 in [22.1 mm]
    Weight 0.22 lbs [100 g]

    Measurement

    SPECIFICATIONS VALUES
    Technique Oscillometric
    NIBP Accuracy Meets ANSI/AAMI SP10, EN 1060-4, ISO 81060-2
    Patient Applications Adult, Pediatric, Neonatal
    Systolic Range
    • Adult: 30-255 mmHg
    • Neonatal: 30-135 mmHg
    Diastolic Range
    • Adult: 15-220 mmHg
    • Neonatal: 15-110 mmHg
    Pulse Rate Range
    • Adult: 30-240 BPM (Beats per min)
    • Neonatal: 40-240 BPM
    Pulse Rate Accuracy ±2% or ±3 BPM, whichever is greater
    Transducer Accuracy ± 3 mmHg over full range in operating conditions
    Operating Modes Manual
    Operating Conditions 0?C to 55?C, 15% to 90%, non-condensing humidity
    Storage Conditions -20?C to +65?C, up to 90% RH non-condensing

    Electrical

    SPECIFICATIONS VALUES
    Operating Voltage 12 VDC ± 5% (High), 6 VDC ± 5%(Low)
    Power Consumption Using 6 VDC Nominal
    • Sleep: 300 mW
    • Idle: 380 mW
    • Measurement: 1.5 W
    • Inflation: 4.5 W (High)
    Communication Protocols TTL (5V)
    Safety & Regulatory Standards IEC 60601-1, IEC/EN80601-2-30, EN60601-1-2:2007, ISO 81060-2:2009

    Advantage Technologies

    SPECIFICATIONS VALUES
    RMT-MAX (Maximum Performance R-wave Motion Tolerance) Yes
    TMT-MAX (Maximum Performance Transport Motion Tolerance) Yes
    VET (Veterinary Monitoring) Yes

    Customer Support

    SPECIFICATIONS VALUES
    Standard Support Yes
    Custom Support 10 hours*
    Custom Design Additional Charge

    Warranty

    SPECIFICATIONS VALUES
    Time 1 year
    Cycles 30000




    久久人妻一区二区免费AV|亚洲A∨无码男人的天堂|亚洲精品资源网在线观看|黄网站色视频免费毛片在线看
    <sup id="2asiy"></sup>
  • <td id="2asiy"></td>
  • <xmp id="2asiy"><td id="2asiy"></td>
  • <table id="2asiy"></table><td id="2asiy"><button id="2asiy"></button></td>
  • <td id="2asiy"><li id="2asiy"></li></td>
  • <td id="2asiy"><li id="2asiy"></li></td>
  • <td id="2asiy"><li id="2asiy"></li></td><table id="2asiy"><li id="2asiy"></li></table>
  • <td id="2asiy"></td>
    <table id="2asiy"></table>
  • <table id="2asiy"><td id="2asiy"></td></table><li id="2asiy"></li>
    <table id="2asiy"></table>
  • <table id="2asiy"><li id="2asiy"></li></table>